Subject:Re: [pcb-rnd] Bug: polygons connected to nets are ignored in DRC
in-reply-to:4316 from Majenko Technologies <ma...@majenko.co.uk>
replies: 4466 from Majenko Technologies <ma...@majenko.co.uk>
 
 
On Tue, 1 Sep 2020, Majenko Technologies wrote:
 
>A polygon connected to a net (for example a ground plane) is ignored by DRC
>clearance tests. In the attached PCB the connection between C101 and C102
>(net LINK) should fail DRC as the clearance is below the specified 0.15mm
>between it and the ground (net GND). But it doesn't.
 
Thanks, fixed in r33178, please test!
 
Note: the short will be reported exactly twice, and that's intentional: it 
is found from both nets point-of-view (that's why the red-blue highlight 
swaps between the two reports). In extreme cases, with more complicated 
drc rules you may find an asymmetric case, e.g. a high voltage network 
requires a 4mm clearance, but plain signals require only 0.2mm, and you 
have 3mm - that way only the high voltage net would flag this as a 
violation.
 
Regards,
 
Igor2
 
 