replies: | 2950 from Peter Stuge <pe...@stuge.se> |
On Fri, 19 Apr 2019, Peter Stuge wrote: >When I open the short.lht that I just sent and then optimize rats, the >message window contains: > >SHORT: net "net1" is shorted to "net2" at terminal J1-2 >Congratulations!! >The layout is complete and has no shorted nets. Funny bug! Fixed in r24725, please test!